UV-Vis-NIR Photometric Transmitter

The CS&T UV-Vis-NIR photometric transmitter line has been designed for easy integration into process monitoring equipment in upstream and downstream processes. Probes and other accessories complete the transmitters and can be customized to meet your process monitoring requirements. The PX2 series incorporates a combination of measurement methods (absorbance, fluorescence, or reflectance), single or dual wavelengths, multiple detectors (PMT, Si, InGaAs) and a variety of light source options (Xenon, LED, Tungsten Halogen) into one compact transmitter including a user-friendly touchscreen color display.

  • Single or Dual LED Wavelengths.
  • Customized Wavelengths from 200 to 2,400 nm
  • Easy Validation/Calibration with liquid or solid NIST standards
  • Long Life LED’s (7+ years)
  • Analog or Digital Communication

  • Chromatography (Pre/Post Column Monitoring)
  • Filtration (NFF/TFF)
  • UF/DF
  • Detect extremely low concentrations of Fluorescent compounds
  • Turbidity/Cell Density
  • Colorimetry
  • Water Analysis (TOC, BOD, COD, NOM)

UV-Vis-NIR photometric transmitter PX2

  • Size: 4” x 4” x 2.5”
  • Wavelength Range: 200-2400nm.
  • Accuracy: +/-2% from 2-3 AU, +/- 1% of full scale or better at 0-2 AU
  • Light Source: LED, Xenon Flash Lamp or Tungsten Halogen
  • Common Wavelengths: 255 nm, 260 nm, 280 nm, 295 nm, 300 nm, 310 nm, other wavelengths are available.
  • Detector: PMT, Si Photodiode, InGaAs Photodiode
  • Communication: Analog (4-20 mA) or Digital (RS485 Modbus)
  • Power Requirements: 24 VDC (12-48 VDC)
  • Operating Temperature: 41°-122° F for UV-Vis (5°-50° C); -4°-90° F for NIR (-20°-32C)

About The CS&T UV-Vis-NIR Photometric Transmitter

The PX2 photometer is a critical tool for any instrument needing in-line UV-VIS-NIR spectroscopy. The PX2 uses a combination of measurement methods, multiple detectors, multiple light sources, and can be used to monitor multiple single or dual wavelength applications. An LED indicator light alerts the user if there is any change in the unit operating status. There is an optional software package which allows the end user to set up their sensor for optimal process measurement requirements.

uv-vis-nir photometric transmitter PX2

  • Bright 3.2” LCD touchscreen display for calibration and monitoring
  • Wavelength Range: 200-2400nm
  • Accuracy: +/-2% from 2-3 AU, +/- 1% of full scale or better at 0-2 AU
  • Light Source: LED, Flash Lamp, Tungsten Halogen (reference)
  • Common Wavelengths: 255 nm, 260 nm, 280 nm, 295 nm, 300 nm, 310 nm, others available
  • Detector: PMT, Si Photodiode, InGaAs Photodiode
  • Communication: Analog (4-20 mA) or Digital (RS485 Modbus)
  • Power Requirements: 24 VDC (12-48 VDC)
  • Operating Temperature: 41°-122° F for UV-Vis (5°-50° C); -4°-90° F for NIR (-20°-32C)

About The PX2+ UV-Vis-NIR Photometric Transmitter

The PX2+ UV-Vis-NIR Photometric Transmitter allows for real-time optical measurements in upstream and downstream processes. PX2+ is available in single or dual wavelengths. Dual LED wavelengths allow for the accurate determination of protein or nucleic acid concentrations. The ability to interrogate a process stream with two wavelengths allows for the detection of low protein concentrations with one wavelength while simultaneously measuring high concentrations of a different protein (high O.D.) with the other wavelength. Dual wavelengths are also useful in determining nucleic acid to protein ratios. From absorption measurements to fluorescent detection, the applications of the PX2+ are endless!

UV-Vis-NIR condensed packaging ProA Sens

  • Size: 4” H x 2.75” W x 3.3” D
  • Wavelength Range: 255-1450 nm
  • Accuracy: +/-2% from 2-3 AU, +/- 1% of full scale or better at 0-2 AU
  • Light Source: LED
  • Common Wavelengths: 255 nm, 260 nm, 280 nm, 295 nm, 300 nm, 310 nm, other wavelengths are available
  • Detector: Si Photodiode, InGaAs Photodiode
  • Communication: Analog (4-20 mA) or Digital (RS485 Modbus)
  • Power Requirements: 24 VDC (12-48 VDC)
  • Operating Temperature: 41°-122° F for UV-Vis (5°-50° C); -4°-90° F for NIR (-20°-32C)

About PX2-DIN – Condensed Packaging

The PX2-DIN-Condensed Packaging gives you all the features of the PX2 but in a significantly smaller footprint for skid manufacturing. The PX2-DIN-Condensed Packaging has an integrated DIN rail mount and has all electrical connections in the front of the unit (easy connection of electrical and fiber optic cable connections). The size is so small that it allows two PX2-DIN-Condensed Packing units to be mounted side-by-side in the same amount as space as a single PX2 unit.

 

flow cell holder

  • Wavelength Range: 200 – 2400 nm
  • Path Lengths: 1 mm, 2 mm, 5 mm, and 10 mm
  • Flow Cell is either Single-Use (Polypropylene, USP Class VI) or Multi-use (316 SS, Titanium, or Hastelloy C.)

About the Flow Cell Holder

The Flow Cell Holder has been designed to easily install a multi-use or single-use flow cell for bioprocess applications. The Flow Cell comes in path lengths of 1 mm, 2 mm, 5 mm, and 10 mm. The Flow Cell Holder has an integrated slot to allow for cuvettes (liquid) or NIST filter standards (solid) to be placed directly in the optical path. Filter standards or cuvettes are used to add a fixed amount of absorbance to the baseline or to allow the end user to calibrate the photometric instrument without having to shut down the process flow.


View all CS&T products